Thanks for the question, Meghana.

Asked: May 04, 2017 - 6:30 am UTC

Last updated: May 11, 2017 - 5:31 am UTC

Version: 11.2.0.3

Viewed 10K+ times! This question is

You Asked

ORA-12535: TNS: operation timed along with this ORA-609 opiodr aborting process as the secondary error.While this error is occurring tnsping takes longer than expected and SQLPLUS / also is taking too much time ,ping using the IP is working fine .There are no evident network glitches or memory/CPU utilization spikes. sqlnet.inbound_connect_timeout parameter has been increased to 240s and inbound_connect_timeout=120s has been added to listener.ora. Still error still persists and connections are getting timeout.

and Connor said...

Take a look at

Troubleshooting Guide for TNS-12535 or ORA-12535 or ORA-12170 Errors (Doc ID 119706.1)

There is a *large* list of potential cause, but it also describes how to setup a detailed level sqlnet trace to identify the cause.